INJECTION MOLDING ENCYCLOPEDIA
Injection Molding Encyclopedia
Find hot runner articles by industry, material, and molding defect.
Frequently Asked Questions
Find products by material
View all four productsTotal 194 articles · Current:All industries
Browse by defect, material, and industry
194 articles
Where is PEEK's thermal margin applied in new energy tri-electric systems?
PEEK (Victrex 650G):, melting point 343°C, nozzle 395°C, barrel zones 375/380–385/390°C, mold temp 170–200°C, drying 120–150°C for 3–5h; barrel requires 400°C). Due to uneven temperature distribution in tri-electric systems, PEEK's thermal margin is cost-effective only in the true hot zone near power modules.
What Does the Extra Cost of PEEK Buy in Board-to-Board Connectors?
PEEK (Victrex 650G):, melting point 343°C, nozzle 395°C, barrel 375/380–385/390°C, mold temperature 170–200°C, drying 120–150°C for 3–5 hours; cylinder requires 400°C). PEEK is used in board-to-board connectors due to its ability to withstand multiple reflow cycles and high mating durability. For single reflow cycles, PPS is more cost-effective.
When Is PEEK Truly Required for Wire-to-Board Connectors?
PEEK (Victrex 650G): Melting point 343°C, long-term use temp ~250°C, nozzle 395°C, barrel 375/380–385/390°C, mold temp 170–200°C, cylinder requires 400°C. Three prerequisites for PEEK in wire-to-board applications: long-term exposure >180°C, specific chemical resistance, and long-term dimensional stability.
Hot Runner Gate Types: SD, TP, VG, and PVG Applications
SD (Open Gate): Low cost, sealed via cold slug with visible mark. TP (Pin Point): Minimal mark, high pressure loss. VG (Valve Gate): Mechanical seal, enables sequential control. PVG: Valve gate variant. PA4T/PA6T/PA9T/PA10T/PA46/PPS: SD only recommended. LCP, PEEK: Compatible with SD/VG/PVG. PEI: Compatible with all four types.
Gate Location: Why "Easy Feeding" Is Not Enough
Gate placement is constrained by four factors: flow ratio (filling capability), weld line location (strength), flow direction (warpage), and end-of-fill position (venting). Multi-drop systems distribute gates based on equal flow lengths, using larger gates at remote ends. Hot runners enable sequential valve gate control, though the processing window for fast-freezing materials is narrow.
PEEK Suckback: Residual Flow After Shutdown
PEEK drooling often appears in initial shots after shutdown or mold changes. PEEK 650G specs: nozzle 395°C, mold temp 170–200°C; both sides remain hot, slowing outlet cooling and allowing residual material to flow out. Covers timing analysis, comparison with LCP, actual drying failure signs, and four-step shutdown procedure.
PEEK Nozzle Clogging: Effect of 395°C Melt vs. 170°C Mold
PEEK 650G specs: nozzle 395°C, mold temp 170–200°C, yielding the largest differential (195–225°C) among five materials, causing rapid tip cooling. Distinguishes between freezing and degradation clogs. Provides three-step diagnosis: temperature measurement, heater band inspection, residence time calculation, plus actionable lists.
PA6T Stringing: Should Melt Temperature Exceed 330°C?
PA6T (Grivory HT1, PA6T/6I) has a tight window: melt 330–340°C, mold temp ≥140°C. Hard, glossy string breaks indicate semi-solidified material tearing. Outlines steps: inspect string shape, measure outlet temp, check gate shear, adjust cut-off position. Explains why SD Series is recommended for this material group.
LCP connector stringing: Is it caused by high melt or mold temperature?
For incomplete LCP connector stringing removal, distinguish between high melt and mold temperatures: LCP E130i melting point 335°C, hot runner 335–345°C, mold temp 80–120°C, with extremely fast solidification. This article outlines the troubleshooting sequence: inspecting string shape, measuring nozzle tip temperature, checking gate shear, and adjusting opening speed, plus cases where lowering mold temperature is ineffective.
LCP Connector Drip: Post-Stoppage Residual Flow
LCP drooling typically occurs in initial shots after stoppage, mold change, or purge due to residual material flowing from the hot nozzle tip. LCP E130i specifications: hot runner 335–345°C, mold temperature 80–120°C. This section covers timing judgment, differentiation from stringing, sealing techniques during stoppage, and scenarios requiring valve pin inspection.
Can't find the matching gate issue? Share material, part, and defect details. Our engineers will evaluate it by part.
Online selection and quote